Pro
Plus_Máy đo nước đa chỉ tiêu cầm tay
Model:
Pro Plus
Code:
6050000
Hãng
sản xuất: YSI – Mỹ
Xuất
xứ: Mỹ
1.
Tính
năng kỹ thuật:
-
The Quatro cable attached to the Pro
Plus allows you to utilize 4-ports to measure temperature/conductivity, DO, and
any two ISEs among pH, ORP, ammonium, chloride, or nitrate creating an
extremely powerful handheld multiparameter instrument.
-
Interested in a Pro Series Product?
Check out the trade in program currently going on (U.S. only).
Toughest:
-
The Pro Plus instrument meets the
demands of true field work. The instrument is rated to IP-67 standards even
without the battery cover on. Other tough features include a 3-year warranty,
Mil-spec connectors, rubber overmolded case, and a 2-year cable warranty.
In-house testing procedures also include 1-meter drop tests from all angles to
ensure expected field-durability.
-
Easy-to-install cable weights; can be
daisy-chained for additional weight*
-
Rubber, over-molded IP-67 waterproof
case (even without the battery cover)*
-
3-year instrument warranty
-
2-year cable warranty*
-
Rugged cables, sensors, and
military-spec connectors*
-
Drop-tested 1 meter at all angles*
-
Scratch-resistant lens; viewable with
polarized glasses
Instrument
floats:
-
Weighted, user-replaceable multi-sensor
design
Smartest:
-
The instrument provides numerous benefits
from the following features; 5,000 data-set memory, password protection,
backlit display and keypad, graphic display with detailed Help functionality,
re-cal prompts, user defined fields, detailed GLP, auto stable, Hold All
Readings function, Data Manager software for the desktop, USB connection,
auto-buffer recognition, and flexible folders and site lists for logging data.
-
5,000 data set memory
-
Detailed on-screen Help function*
-
Free, Data Manager desktop software and
ProComm II saddle*
-
Interval or single-event logging
-
100 folder & site list data
structure*
-
Password protection
-
Detailed GLP data
-
USB connection also powers the
instrument
-
6-point cal with auto-buffer
recognition*
-
User-adjustable auto-stable with
prompts*
-
User-upgradeable software via waterproof
USB port
-
Recalibration prompts
-
Search function filters user-defined
data information*
-
Backlit display AND keypad*
-
Cable management kit included with all
cables from 4- to 30-meters*
Most
Versatile:
-
Connect any Professional Series cable
(excludes ODO cables) and probe option to the instrument and use the convenient
cable management kit to keep everything simple and organized. Cable options
range from 1-, 4-, 10-, 20-, and 30-meter choices (up to 100-meters on DO only
cables). Use lab or field probes and switch between the two quickly. The Pro
Plus makes an ideal lab BOD instrument with the proven self-stirring BOD probe.
A convenient handstrap can be used on either side of the instrument. A complete
family of accessories also increases the versatility of the Pro Plus. Choose
among accessories including carrying cases, flow cells, cable weight, belt
clip, tripod, and c-clamp.
-
Adjustable right- or left-handed hand
strap*
-
Multiple user-replaceable sensor options
and a choice of DO sensors*
-
Multiple parameter options and cable
lengths
-
Lab-grade ISE sensors and BOD probe
available to make a true lab/field instrument
-
Languages - English, Spanish, German,
French, Italian, Norwegian, Portuguese, Japanese, Chinese (Simplified and
Traditional)
-
Wide array of accessories are available
from flow cells, to shoulder straps, to carrying cases
2.
Thông
số kỹ thuật:
|
Autostable
|
User-defined auto-stable function
holds stable readings on display when criteria is met
|
|
Certifications
|
VCCI, FCC, C-Tick, 1-meter drop
test, Assembled in USA, IP-67, WEEE, RoHS, CE
|
|
Connectivity
/ Communications
|
ProComm II communications saddle
and USB cable included, user-upgradeable software via USB and website, USB
2.0
|
|
Connector
|
MS (military spec) waterproof with
bayonet lock
|
|
Data
Management
|
Data Manager desktop software
included; 100 user-defined folders and site namesMinimum PC
requirements;•Windows 2000 with SP4 (minimum) or XP with SP2 (minimum)•300
MHz or higher Pentium-compatible CPU•128 MB of RAM or higher•80 MB or more of
free hard-disk space•USB 2.0•Microsoft.NET (installed with Data Manager)
|
|
Desktop
Software Compatible
|
100 user-defined folders and site
names Minimum PC requirements, •Windows 2000 with SP4 (minimum) or XP with
SP2 (minimum) •300 MHz or higher Pentium-compatible CPU •128 MB of RAM or
higher •80 MB or more of free h, Data Manager desktop software included
|
|
Digital
/ Digital Sensors
|
Analog
|
|
GLP
Compliance
|
detailed GLP information is stored
and is available to view, download or print, Yes
|
|
Graphic
Display
|
backlit display AND keypad,
Graphic display with detailed Help
|
|
Languages
|
English, Portuguese, Italian,
German, Chinese (Simplified and Traditional), French, Japanese, Spanish,
Norwegian
|
|
Logging
Capabilities
|
Single or Continuous
|
|
Measurement
Range
|
Dissolved Oxygen % air
saturation-0 to 500% Temperature--5 to 70°C Conductivity-0 to 200 mS/cm
Salinity-0 to 70 ppt pH-0 to 14 units ORP-1999 to +1999 mV Ammonium-0 to 200
mg/L-N Nitrate-0 to 200 mg/L-N Chloride-0 to 1000 mg/L Total Dissolved
Solids(TDS)-0 to 100 g/L Barometer-375 to 825 mmHg
|
|
Memory
|
100 GLP files, 5,000 data sets
(data, date, time, user-defined info)
|
|
Multiparameter
|
Yes
|
|
Operating
pH Range
|
0 to 14 units
|
|
Operating
Temperature
|
-10 to 60°C
|
|
Parameters
Measured
|
Temperature, Dissolved Oxygen, pH,
ORP/Redox, Conductivity, TDS, Ammonia, Ammonium, Nitrate, Chloride,Built-in
barometer
|
|
Power
|
2 alkaline C-cells provide 80
continuous hours at ambient temperature without backlight, ProComm II saddle
provides USB power or optional wall power, cigarette lighter, and universal
cell phone charger options
|
|
Sampling
|
Yes
|
|
Storage
Temperature
|
-20 to 70°C
|
|
Unit of
Measure
|
°F, Temperature- °C,
Barameter-mmHg, Nitrate-mg/L-N, Dissolved Oxygen-%, Chloride-mg/L, air
saturation, ORP-mV, Total Dissolved Solids(TDS)-g/L, Ammonium-mg/L-N,
Salinity-ppt, mg/L, pH-units, Conductivity-mS/cm
|
|
User
Calibratable
|
Yes
|
|
User
Replaceable
|
Yes
|
|
Warranty
|
3-year instrument; 2-year field
cables
|
|
Waterproof
|
IP-67 (even with the battery cover
off), floats
|
|
Specification
|
|
|
Barometer
|
Built-in barometer
|
|
Buffer
Recognition
|
Auto buffer recognition for US and
NIST buffers
|
|
Cables:
Field
|
Standard lengths of 1, 4, 10, 20,
or 30 meters - up to 100 meters on DO only cables; 4- through 30-meter
cables include a cable management kit
|
|
Cables:
Lab
|
BOD sensor includes 2-meter cable;
1 or 4 meters on lab pH, ORP and pH/ORP cables
|
|
Certifications
|
RoHS, CE, WEEE, C-Tick, VCCI, FCC,
IP-67, 1-meter drop test, Assembled in USA
|
|
Connectivity
|
USB 2.0; ProComm II communications
saddle and USB cable included; user-upgradeable software via USB and website
|
|
Connector
|
MS (military spec) waterproof with
bayonet lock
|
|
Data
Management
|
Data Manager desktop software
included; 100 user-defined folders and site names. Minimum PC requirements:
·
Windows
2000 with SP4 (minimum) or XP with SP2 (minimum)
·
300 MHz
or higher Pentium-compatible CPU
·
128 MB
of RAM or higher
·
80 MB or
more of free hard-disk space
·
USB 2.0
·
Microsoft.NET
(installed with Data Manager)
|
|
Data
Memory
|
5,000 data sets (data, date, time,
user-defined info); 100 GLP files
|
|
Dimensions
|
8.3 cm width x 21.6 cm length x
5.6 cm depth (3.25 in x 8.5 in x 2.21 in)
|
|
Display
|
Graphic display with detailed
Help; backlit display AND keypad
|
|
DO
Membrane Response Times(T95; 100%-0) and Flow Dependence
|
1.25 mil PE = 8 seconds and 6
in/sec flow
2.0 mil PE = 17 seconds and 3 in/sec flow 1 mil Teflon® = 18 seconds and 12 in/sec flow |
|
DO
Sensors
|
Polarographic or galvanic field
sensors; self-stirring polarographic BOD sensor for the lab
|
|
Flow Cell
|
Single, dual and multiparameter
Quatro cable all flow cell compatible
|
|
GLP
Compliance
|
Yes; detailed GLP information is
stored and is available to view, download or print
|
|
Languages
|
English, Spanish, German, French,
Italian, Norwegian, Portuguese, Japanese, Chinese (Simplified &
Traditional)
|
|
Logging
Modes
|
Single point or Continuous
|
|
Power
|
2 alkaline C-cells provide 80
continuous hours at ambient temperature without backlight; ProComm II saddle
provides USB power or optional wall power, cigarette lighter, and universal
cell phone charger options
|
|
Temperature: Operating
|
-10 to 60°C (14 to 140°F)
|
|
Temperature: Storage
|
-20 to 70°C (-4 to 158°F)
|
|
User ID
|
Optional user ID for data security
|
|
Warranty
|
3-year instrument; 2-year field
cables
|
|
Waterproof
|
IP-67 (even with the battery cover
off); floats
|
|
Weight
|
475 grams (1.05 lbs)
|
3.
Thông
tin đặt hàng:
·
Step
1: Order Instrument
|
SKU
|
Description
|
|
6050000
|
Instrument, includes Data Manager
software, the ProComm II communications saddle, and USB cable
|
·
Step
2: Order Cable(s)
|
SKU
|
Description
|
|
60510
|
1, 4, 10, 20 or 30 meter: ISE*/temp
|
|
60520
|
1, 4, 10, 20, 30 or up to100
meters**: DO/temp
|
|
60530
|
1, 4, 10, 20 or 30 meter:
conductivity/temp
|
|
6051010
|
1, 4, 10, 20 or 30 meter:
ISE/ISE/temp
|
|
6051020
|
1, 4, 10, 20 or 30 meter: ISE/DO/temp
|
|
6051030
|
1, 4, 10, 20 or 30 meter:
ISE/conductivity/temp
|
|
6052030
|
1, 4, 10, 20 or 30 meter:
DO/conductivity/temp
|
|
605790
|
1, 4, 10, 20 or 30 meter:
ISE/ISE/DO/conductivity/temp
|
|
605107
|
1–meter single junction pH sensor
& cable
|
|
605177
|
4–meter single junction pH sensor
& cable
|
|
605108
|
1–meter single junction ORP sensor
& cable
|
|
605178
|
4–meter single junction ORP sensor
& cable
|
|
605109
|
1–meter single junction pH/ORP
sensor & cable
|
|
605179
|
4–meter single junction pH/ORP
sensor & cable
|
·
Step
3: Order Sensor(s)
|
SKU
|
Description
|
|
605202
|
Galvanic DO
|
|
605203
|
Polarographic DO
|
|
605780
|
Self-stirring BOD (2-meter cable
included)
|
|
605101
|
pH (ISE)
|
|
605102
|
ORP (ISE)
|
|
605103
|
pH/ORP combination (ISE)***
|
|
605104
|
Ammonium (ISE)
|
|
605105
|
Chloride (ISE)
|
|
605106
|
Nitrate (ISE)
|
** Special order cables in 10-meter increments up to 100 meter available
*** Not recommended on 6051010 or 605790 cables. Only pH would appear
Không có nhận xét nào: